The High Voltage, Inc PFT-303CM(F) 0 – 30kVac @ 3kVA test set is a single piece unit. All the 3kVA AC Hipots are compensated enabling testing of 3kVA loads with a power draw of 1.5kVA

Input: 120V, 60Hz, 15A or 230V, 50/60Hz, 8A
Output: 0 – 30kVac, 100mA, 1kVA resistive load, 3kVA capacitive load
Duty: 3kVA: 1 hr on, 1 hour off; 1kVA continuous
Voltmeter: 3.5″, scaled 0-12/30kVac, ±2% FS accuracy
Currentmeter: 3.5″, scaled 0-1mAac, ±2% FS with multipliers x1, x10, x100
Guard/ground load return: 14mA at full current in ground mode
Controls
Voltage output: Continuously adjustable up to max. voltage
Safety
Interlocks: Zero start and external interface
Protection: Surge and transient
Cable Length
Output cable: 6m shielded with alligator clamp and hook
Size & Weight
Controls: 533mm w x 286mm d x 387mm h, 34kg
HV Tank: Included in controls case